Before You Start

This app can only work with the information provided and is not responsible for inaccurate outcomes. Data is accurate to the most recent app update. Engineers must adhere to guidelines as specified in their industry training. This app is an assistive tool that is under constant upgrade.

Admin Settings
Admin credentials are stored (hashed) only in this browser's local storage — there is no server.
Create the Admin Account
No admin account exists in this browser yet. Set one up now — it's stored only here, never written into the app itself.
Admin Dashboard
Opens your Cloudflare dashboard in a new tab -- once logged in, go to Analytics & Logs → Web Analytics to see visits for hvacmate.co.uk.
Feedback
Your Previous Feedback
You haven't submitted any feedback yet.
This app is built on positive, constructive feedback — let us know what's working, what isn't, or what you'd like to see next.
Thank you for your comments!
Your feedback has been sent -- we appreciate it.
HVAC Mate logo

HVAC Mate

HVAC Mate
Domestic Heating
HVAC Mate
Fault Finding
HVAC Mate
Boiler
HVAC Mate
Series
Commissioning Data (Natural Gas)
Detail
Ariston — Fault Finding
Common faults, codes and recommended actions. Always confirm against the appliance's own fault code sticker or manual, and follow safe isolation procedure before investigation.
101
Overheat / safety thermostat tripped
Check pump operation, system flow, and NTC sensors; reset once cause is resolved.
108
Air pressure switch fault / blocked flue or air inlet
Check flue and terminal for blockage, inspect fan and pressure switch tubing/contacts.
109
Air pressure switch stuck closed before fan starts
Check pressure switch wiring and tubing for damage; replace switch if it fails to open.
501 / 502
No ignition / loss of flame during operation
Check gas supply and inlet pressure, ignition electrode gap and condition, and earthing/polarity.
605
Flow (NTC) sensor fault
Check NTC sensor resistance against manufacturer chart and wiring continuity; replace if out of range.
203
Return sensor fault
Check return NTC sensor resistance and connector; replace if faulty.
Low pressure indicator
System water pressure low
Re-pressurise via filling loop, check for leaks and correct expansion vessel charge.
Baxi — Fault Finding
Codes below are from the Baxi Duo-tec Combi 24 / 28 / 33 / 40 HE A manual (section 18.0); the Megaflo System uses the same codes except E50 (no DHW sensor). Other Baxi boilers (EcoBlue, 200 / 400 / 600 / 800, Duo-tec 2 GA) use different or additional codes — confirm against that boiler's own manual. Follow safe isolation procedure before investigation.
E20
Central heating NTC fault
Faulty component. Check CH sensor cold resistance ≈ 10 kΩ at 25 °C (falls as temperature rises); replace if out of range.
E28
Flue NTC fault
Faulty component. Flue sensor cold resistance ≈ 20 kΩ at 25 °C; replace if out of range.
E50
Hot water NTC fault
Faulty component. DHW sensor cold resistance ≈ 10 kΩ at 25 °C; replace if out of range.
E110
Safety thermostat operated (primary overheat)
Reset (selector to Reset for 5 s). If it returns: allow to cool and check continuity across the thermostat (< 1.5 Ω); replace thermostat or PCB. Check pump and circulation.
E119
Water pressure switch not operated (pressure < 0.5 bar)
Re-pressurise. If pressure is OK check the switch wiring (COM–NO, PCB X400 terminals 3 & 4) and replace the switch; check the auto air vent tap is open.
E125
Circulation fault (primary circuit)
Shown if CH temp has not risen 1° within 15 s of burner lighting, or exceeds the set temp by 30° twice within 10 min. Check pump (230 V at pump and PCB X3 terminals 3 & 4; free it if jammed), 3-way valve motor, blockages.
E130
Flue NTC operated (flue overheat)
Reset (selector to Reset 5 s). Check flue sensor (≈ 20 kΩ at 25 °C) and CH sensor; if sensors are OK check the heat exchanger for obstruction.
E133
Gas interrupted / ignition failed / flame not detected
Reset. Check gas on and supply pressure (more than 10–11 mbar working), venturi–gas valve tube, spark at electrode (spark gap 4 ± 0.5), igniter and PCB (at least 100 V DC at X2 terminals 2 & 5), flame sensing electrode and lead (flame current more than 0.5 µA), and CO2 setting.
E160
Fan or fan wiring fault
Check fan connections and 230 V at PCB X2 terminals 3 & 4; check fan speed feedback at PCB X401 terminals 5, 6, 7 & 8. Replace fan if jammed or faulty winding, otherwise PCB.
E193
Pre-circulation fault
Check pump runs and primary circulation is clear (pump 230 V, 3-way valve motor 230 V at PCB X3 terminals 5 & 6 in CH / 5 & 7 in DHW), and no blockage.
Glow-worm — Fault Finding
Common faults, codes and recommended actions. Always confirm against the appliance's own fault code sticker or manual, and follow safe isolation procedure before investigation.
F1
Low system water pressure
Re-pressurise via filling loop; check for leaks and expansion vessel charge.
F2
Flame failure / no ignition
Check gas supply, inlet pressure, and ignition electrode condition and gap.
F4
NTC flow/return sensor fault
Check sensor resistance against chart and connector condition; replace if faulty.
F9
Fan speed / air pressure fault
Check flue/terminal for blockage and fan wiring; verify pressure switch operation.
F22
Low water pressure detected during operation
Same as F1 — check for leaks before repressurising repeatedly.
F28
Failed ignition (lockout after repeated attempts)
Check gas rate/pressure, electrode, and flue condition; investigate condensate blockage.
F75
Pressure sensor fault / no pressure rise detected
Check pump operation and pressure transducer wiring/connection.
Vaillant — Fault Finding
Common faults, codes and recommended actions. Always confirm against the appliance's own fault code sticker or manual, and follow safe isolation procedure before investigation.
F.22
Low system water pressure
Re-pressurise via filling loop; check for leaks and expansion vessel charge.
F.28
Fault on ignition / no flame detected at start-up
Check gas supply and pressure, ignition electrode, and earthing/polarity.
F.29
Flame loss during operation
Check gas rate, condensate trap for blockage, and flue terminal for obstruction.
F.61
Gas valve fault
Check gas valve wiring and operation; replace valve if it fails to open/close correctly.
F.75
Pump/pressure rise not detected
Check pump for airlock or seizure, and pressure sensor wiring.
F.32
Fan speed fault
Check fan operation, wiring, and flue for restriction.
F.83
Communication fault (appliance to control/PCB)
Check control wiring/connections; reset and reflash/replace PCB if fault persists.
Worcester Bosch — Fault Finding
Common faults, codes and recommended actions. Always confirm against the appliance's own fault code sticker or manual, and follow safe isolation procedure before investigation.
EA
No ignition / flame not detected at start-up
Check gas supply and pressure, ignition electrode gap/condition, and earthing/polarity.
D5
Low system water pressure
Re-pressurise via filling loop; check for leaks and expansion vessel charge.
C6
Fan fault (speed feedback not matching demand)
Check fan wiring/connector and flue for restriction; replace fan if faulty.
F7
Flow/return temperature sensor mismatch or fault
Check sensor resistance against chart and pump operation for restricted flow.
A1
Frost protection activated / low return temperature
Usually not a fault in cold weather; check system flow and sensors if it occurs when warm.
H07
Waiting for external control / no demand signal
Check room thermostat/programmer wiring and settings.
228
Ignition lockout after repeated failed attempts
Check gas rate/pressure, electrode, and condensate trap for blockage/freezing.
Remeha — Fault Finding
Codes from the Quinta Pro manual (123157 v.11) and the original Quinta 115 technical information. Note the code before resetting. Follow safe isolation procedure before investigation.
Quinta Pro — lock-out codes (E:xx)
Reset
How to reset
Press RESET for 2 seconds. If the display shows the power symbol instead of RESET, switch the boiler off, wait 10 seconds and switch on again.
E:00 / E:01
Parameter storage unit (PSU) not found / safety parameters not OK
Check wiring; replace the PSU if faulty.
E:02 / E:03
Flow temperature sensor short circuit / open
Check wiring, that the sensor is fitted correctly; replace the sensor if faulty.
E:04 / E:05
Heat exchanger temperature too low / too high
Check wiring and sensor. Check circulation: vent the CH system, pump, valves, water pressure, heat exchanger cleanliness, boiler type parameter.
E:06 / E:07
Return temperature sensor short circuit / open
Check wiring and sensor fitting; replace the sensor if faulty.
E:08 / E:09
Return temperature too low / too high
Check wiring, sensor and circulation (vent, pump, valves, water pressure, heat exchanger).
E:10 / E:11
Flow – return temperature difference too great
No circulation: vent system, check pump operation, valves, water pressure, heat exchanger cleanliness; check the sensors.
E:12
Heat exchanger above normal range (STB high limit) / air pressure switch tripped
Check wiring and sensor, circulation, and — if fitted — that the air supply and flue outlet are not blocked.
E:14
Five failed burner starts
No spark: ignition transformer cabling, ignition / ionisation electrode, earthing, burner cover, SU PCB. Spark but no flame: vent the gas, gas valve fully open, supply pressure, gas valve setting and wiring, air / flue blockage. Flame but poor ionisation: check electrode, earthing and wiring.
E:15
Five failed gas leakage checks (VPS fitted)
Gas supply / tap open, wiring, VPS switch setting or fitting, faulty VPS or gas valve.
E:16
False flame signal
Ionisation without flame: check electrodes, ignition transformer, gas valve. Burner very hot: O2/CO2 too high — adjust settings.
E:17
Gas valve error in SU PCB
Check wiring; replace the SU PCB if defective.
E:34
Fan operation error
Check wiring and chimney draw; replace the fan if defective.
E:35
Flow and return reversed
Check connections, sensors, and circulation direction (pump, valves).
E:36
Five flame losses
No ionisation: vent gas, gas valve open, supply pressure, gas valve setting, air supply / flue blockage, flue gas recirculation.
E:37 / E:38
Communication error with SU PCB / SCU PCB
Check the PCB fitting in its connector and the wiring; replace the SCU PCB if faulty.
E:39 / E:40
Blocking input in lock-out / heat recovery unit test fault
Check wiring, remove the external cause, check parameters.
Quinta Pro — blocking codes (Su:xx)
Info
Blocking = temporary
The boiler retries starting and returns to operation by itself once the cause is removed. Read out with the two menu keys, confirm, then press [+] to show the Su code.
Su:0
Parameter error on the PSU PCB
Reset and restore parameters with Recom.
Su:1 / Su:2
Maximum flow temperature exceeded / rise too fast
Check flow direction, pump, valves, water pressure and heat exchanger cleanliness; check sensors.
Su:7
Flow – return difference exceeded
Check flow, water pressure, heat exchanger, sensors.
Su:8 / Su:10 / Su:11
No release signal / blocking input active / frost protection input
Remove the external cause, check parameters and wiring.
Su:9
Phase and neutral reversed
Invert phase and neutral; on floating or 2-phase networks set parameter P43 to 0.
Su:13 / Su:21
Communication error with SCU / SU PCB
Check BUS wiring and PCB connectors; carry out automatic detection if the SCU is not recognised.
Su:14
Water pressure too low
Check and top up the water pressure.
Su:15
Gas pressure too low
Check gas valve fully open, supply pressure, and the GPS gas pressure switch fitting.
Su:16 – Su:20
Configuration errors
Wrong SU / PSU / PCU PCB or parameters (Su:20 is a short start-up configuration — no action). Replace the PCB or reset parameters.
Su:22
No flame during operation
Vent gas, gas valve open, supply pressure, gas valve setting, air / flue blockage, flue gas recirculation.
Su:25
SU PCB internal fault
Replace the SU PCB.
Original Quinta 115 — fault codes
00
Flame simulation
Gas valve shuts but burner still glows (incorrect combustion), or valve leaks on shut-down.
01
Short circuit 24 V
Check wiring.
02
No flame / no ionisation after 5 start attempts
No spark: ignition cable and cap, electrode gap (3 – 4 mm), earthing. Spark, no flame: gas cock, inlet pressure, vent pipe, gas valve energised, electrode, gas/air ratio, condensate siphon, flue / air blockage. Weak ionisation (< 2 µA): flame core, CO2 at part and full load, probe condition.
04 / 05
Voltage failure after lock-out / external influence
Check the read-out table for the original cause; check EMC.
08 / 40
Setting failure
Check parameter D (second digit must be 0).
11
Internal communication bus failure
Short circuit in flat cable, water on the display, EMC.
12
Safety interlock
Interlock on terminals 10 and 14 tripped or wire bridge removed; check fuse F2.
18 / 19
Flow / return temperature too high
Check water flow, trapped air, sensor resistance, water pressure (min 0.8 bar).
24
Return temperature above flow
Flow sensor fitted badly, pump running the wrong way or flow / return crossed.
28 / 29
Fan not running / fan speed wrong
Fan or motor failed, poor cable connections, flue draught too high.
31 / 32 / 34
Flow / return / outside sensor short circuit
Check the sensors and wiring.
36 / 37
Flow / return sensor open circuit
Check the sensors and wiring.
77
Ionisation failure during operation
After 4 restarts in one heat demand: flue gas recirculation, insufficient air or gas flow, incorrect combustion.
Worcester GB162 — Fault Codes
Codes from the GB162 installation and servicing manuals. Hold the reset key until "rE" shows to clear an interlock fault, once the cause is fixed. The V2 shows 3 or 4 characters plus a number (e.g. CE207). The original GB162 shows a code and sub-code (e.g. 2E / 207).
GB162 V2 — status and general
--200 / --201 / --203 / --208
Heating mode / DHW mode / standby / chimney sweep mode
Normal operation. No action.
--202 / --204
Waiting: heat demand more than once per 10 minutes / flow temperature above the set boiler temperature
Check the boiler temperature, heating curve and cylinder sensor wiring.
--212 / --260
Flow or safety sensor temperature rising too fast / no temperature rise after burner start
Check pressure, vent the system, check flow, pump and sensor.
H07 / CE207
Water pressure too low
Top up to 2 bar, vent, check the expansion vessel, leaks and the pressure sensor.
d3 / d32322
External switching contact opened
Check the jumper and the external contact.
Fd2313
Mains interrupted during an interlocking fault
Reset the boiler.
F73282
Brief power failure
Check for interference and the electrical installation.
C42732
Switched off for up to 2 minutes after 24 hours of continuous running
Safety check. No action.
GB162 V2 — sensors and overheat
E22223 / E22233
Flow sensor contacts shorted / interrupted
Check the plug, replace the sensor.
d12403 / d12413
Return sensor contacts shorted / interrupted
Check pressure, venting, flow, the sensor plug and cable; replace the sensor.
A33173 / E93183
Flue gas sensor short circuit / contacts interrupted
Check and replace the flue gas sensor.
E52183 / d42863
Flow sensor / return sensor above 105 °C
Check pressure, vent, flow, pump and sensor plug.
E92762 / E92772 / E92852
Flow / safety / return sensor above 95 °C
Check pressure, vent, flow, pump and the sensor.
E92193 / E92203 / E92213
Safety sensor above 105 °C / shorted or above 130 °C / contacts interrupted
Check pressure, vent, flow and pump. For 221 check the plug and replace the sensor.
E92103
Flue gas temperature too high and sensor open
Check the sensor, clean and service the boiler, check the non-return valve.
E92243
Device thermostat temperature too high and open
Check the flow, burner gaskets, heat exchanger and gas / air ratio.
d42133 / d42712
Flow or return temperature rising too fast / flow and safety sensor difference too high
Check pressure, vent, flow and pump / sensor cabling.
GB162 V2 — fan, ignition and gas
C12642
No control signal or power to the fan during operation
Check the fan plug and cabling; replace the fan if needed.
C62153 / C62163 / C72143 / C72173
Fan speed too high / too low / not running at start / irregular at start
Check the fan and BCU plugs and cabling. Replace the fan, then the BCU, if it repeats.
EA2272 / EA2292
Insufficient ionisation current after ignition / while burning
Check soiling, gas pressure, gas / air ratio, the ionisation pin and ignition device.
EA2613 / EA2693
Burner control unit (BCU) faulty / ignition device on too long
Check the plug and wiring. Replace the BCU.
EA2343
Gas valve contacts interrupted
Check 24 V cabling, thermostats and the gas valve, then the BCU.
F72283
Ionisation current measured before burner start
Check the ionisation pin and ignition device; replace with gaskets.
FA3063
Ionisation current after the burner went out
Inspect the ionisation part, check the gas / air ratio and gas valve voltage, replace the BCU.
CE2663
Pump test failed
Check pressure, vent, flow, the pump and the pressure sensor.
GB162 V2 — control unit and KIM
9A235 / 9A360 / 9A361
KIM too new for / incompatible with the BCU
Fit the correct KIM or a BCU with newer software.
9U2333 / b72573 / F02373 / F02393 / F02423 / F02783 / EC2563
BCU or KIM faulty (F02783 is sensor test failed)
Check the plug and wiring. For F02393 also check 24 V cabling and thermostats. Replace the BCU.
Original GB162 (UBA 3 / BC10) — water, flow and fan
2E / 207, H/7, P/-
System pressure below 0.2 bar / below 1.0 bar / above 4.0 bar or no pressure sensed
Check the pressure and top up or reduce.
2F / 260, 2F / 271, 2P / 212, 2U / 213
No flow temperature rise / sensor difference too high / flow rising over 5 °C/s / flow-return difference over 50 °C
Check the flow, pump and vent the system. These clear by themselves.
2Y / 281, 2Y / 282
Pump stopped or running without water / no feedback from the pump
Check the pump, its wiring and for air.
3A / 264, 3L / 214, 3P / 216, 3Y / 215
Fan tacho signal failed / absent / fan too slow / too fast
Check the fan and its wiring. 3L, 3P and 3Y need a reset.
3C / 217
No air flow after a set time (reset)
Check the fan, the flue and condensate drain.
3F / 273
Safety shutdown after 24 hours of continuous running
Normal safety shutdown.
Original GB162 — temperature limiters and ignition
4A / 218, 4F / 219, C/A / 286
Flow / safety / return sensor above 105 °C (reset)
Check the flow, vent and pump.
4L / 220, 4P / 221, 4U / 222, 4Y / 223
Safety sensor contacts shorted or above 130 °C / interrupted (reset)
Check the plug and sensor.
4C / 224
Bridge cable missing between terminals 22 and 24 (reset)
Fit or check the bridge.
4E / 278
Sensor test failed (reset)
Check sensor cabling and sensors.
6A / 227
Insufficient ionisation current at ignition (reset after four attempts)
Check the gas supply, ignition and electrodes.
6C / 228, 6C / 306
Ionisation current before burner start / after shutdown (reset)
Check the electrode and gas valve for leaking.
6L / 229, 6Y / 203, 6P / 269
Ionisation low in operation / too high / glow ignitor on over 10 minutes
Check the gas pressure, electrode and ignitor.
7C / 231
Power interrupted during a locking fault (reset)
Reset the boiler.
9L / 234
Gas valve contacts broken (reset)
Check the gas valve cabling.
C/U / 240
Return sensor contacts shorted (reset)
Check the return sensor.
Original GB162 — control unit, sensors and communication
7L / 261, 7L / 280, 9A / 235, 9H / 237 / 267 / 272, 9L / 238, 9P / 239, 9U / 233, E/L / 290, E+digit / 242
UBA 3 or KIM defective (most need a reset)
Reset, then replace the UBA 3 or KIM if it repeats.
A0 / 800, 808, 809, 810
Outdoor sensor / DHW sensor / DHW sensor 2 / boiler water not warming up
Check the sensor and wiring. 810: check the filling pump.
A0 / 816, A1 / 816, A2 / 816, A3 / 816
No connection to EMS or BC10 / WM10 / RC25 / MM10 communication fault
Check the bus cable and module.
A1 / 802 – 827, A2 / 806, A3 / 807
RC35 / RC25 / heating circuit sensor faults, addresses and time or date not set
Check the controller address and settings, and sensor wiring.
r/e
Reset carried out
Shown for 5 seconds.
Ideal Imax Xtra 2 — Fault Codes
Codes from the Imax Xtra 2 Installation & Servicing manual (UIN 224947). Faults show in the banner on the operating page. Blocking faults clear by themselves. Lockout faults need RESET on the fault page once the cause is cleared. Fault history: Menu > Service.
Sensors
10
Outside sensor
Check the wiring and sensor.
20
Flow sensor
Check wiring continuity, the sensor and the connector pins.
26
Header sensor
Check the wiring and sensor.
28
Flue sensor
Check wiring, sensor and pins, flue blockages and the water flow through the boiler.
30 / 32 / 260
CH circuit 1 / 2 / 3 sensor
Check the wiring and sensor.
40
Return sensor
Check wiring continuity, the sensor and the pins.
50
DHW sensor
Check the wiring and sensor.
431
Heat exchanger sensor
Check the wiring, sensor and pins. Sensor values: 25 kΩ at 5 °C and 12 kΩ at 20 °C.
Overheat, water and pumps
109 / 125
Overheat blocking
Check pump wiring and the 240 V supply, the impeller and the isolation valves. Fill to 1.0 bar and vent. Check the temperature differential.
110
Overheat lockout
As 109, then reset the lockout. Also check the HV interlock input.
270 / 433
High / too-high heat exchanger temperature
Check pump wiring and supply, impeller, isolation valves, and fill and vent the system.
119
Low water pressure
Check the pressure sensor wiring and the sensor.
121 / 122
CH circuit 1 / 2 temperature not reached
Check the pump, mixing valve, wiring and blockages.
126 / 127
DHW / anti-legionella temperature not reached
Check the DHW pump and for blockages.
105 / 111
Service due
Contact Ideal Boilers on 01482 498660.
Ignition, flame, fan and air
128
Flame loss
Check the flue seal and connection, the detection electrode and the gas valve for blockage.
133
Ignition lockout
Check the gas supply, the supply to the gas valve and the spark generator. Clean the spark electrode and set the gap to 3.5 mm.
384
False flame lockout
Check the detection electrode.
160 / 129 / 386
Fan fault
Check the fan wiring to the fan and PCB, and continuity.
162 / 166 / 387
Air pressure switch fault
Check the flue, condensate pipe, burner, sensing pipes, and the switch and its wiring.
193
LV interlock
Check the input state.
Power and earth
146 / 317
Mains frequency fault
If on a local generator, confirm 50 Hz. Otherwise check the primary PCB.
151 / 432
No earth to boiler
Check the incoming and internal wiring.
385
Low mains voltage
Check the mains supply.
Blank display
230 V fuse may have blown
The fuse can blow if a pump draws more than 1 A.
Communication and configuration
81 / 83
LPB wiring fault / BSB wiring fault
Check the wiring and module. For 83 check between the primary PCB, user interface PCB and extension modules.
82 / 84
Slave boiler / extension module address fault
Give each slave or module a unique address.
91
Primary PCB fault
Replace the primary PCB.
100
More than one master
Make sure no slave has address 0.
152 / 153 / 183
Primary PCB setup fault
Reconfigure the primary PCB.
325 – 328
Same sensor or valve configured more than once
Remove the duplicate.
330 – 338 / 388 / 427
Sensor input, DHW sensor or flue gas damper not configured
Configure the input.
351
Primary pump address error
Set the primary pump address correctly.
98 / 99
CH circuit 1 / 2 mixing valve fault
Check the wiring and the extension module.
373
0-10 V pump module fault
Check the wiring and module.
391 – 393
Room thermostat 1 – 3 fault
Check the wiring and thermostat.
0
No active fault
A blocking fault has reset itself. Check the fault history.
Ideal Evomax 2 — Fault Codes
Codes from the Evomax 2 Installation & Servicing manual (UIN 219458), section 5. B = blocking (clears by itself), W = warning, L = lockout (reset needed). Codes are also the OpenTherm error codes.
Thermistors and sensors
1 / 2
Flow thermistor open / short circuit (B)
Check the flow thermistor and wiring (manual section 5.9).
3 / 4
Return thermistor open / short circuit (B)
Check the return thermistor and wiring (section 5.9).
5 / 6
Flue thermistor open / short circuit (B)
Check the flue thermistor and wiring.
7 / 8
DHW thermistor open / short circuit (W)
See manual section 5.12.
9
Outside thermistor defect (W)
See manual section 5.10.
10
Water pressure sensor defect (B)
Check the sensor and wiring.
11 – 18
Flow, return, flue and heat thermistor open / short circuit (L)
Lockout after 24 hours of the same fault as codes 1 – 6. Section 5.9.
Temperature supervision
30 / 31 / 32
Blocking due to flow / return / flue overheat (B)
Overheat flowchart, section 5.3 (flue overheat: no section given).
33
Flow and return reversed (B)
See manual section 5.11.
36 / 38
Flow gradient supervision / delta temperature flow to return (B)
Section 5.3.
37
Flue gradient supervision (reserved) (B)
No action given.
39 / 40
Lockout flow / return overheat (L)
Section 5.3: fill and vent, open isolation valves, check the flow and return differential (over 30 °C is a fault), check the pump turns freely, then restart.
Flame, fan and system
51
Low water pressure (B)
Section 5.6.
52
No flame signal at start (W)
Boiler restarts. Section 5.7.
53 / 54
Flame loss during operation (W endless restarts / L lockout after restarts)
Section 5.7.
55 / 56
Flame loss during stabilisation (W restart / L lockout after restarts)
Section 5.7.
57
False flame with heat demand (L)
Section 5.7 and the false flame lockout flowchart (error 20).
58
No flame after restarts (L)
Ignition lockout flowchart, section 5.4: check the gas pressure at the boiler (over 18 mbar), the detection electrode and harness, and the condensate pipe.
59 / 60 / 61 / 62
Fan faults: stand-still check, speed not achieved, speed error during pre-purge, min / max supervision
Section 5.8. 59 and 61 can lock out; 62 restarts.
63 / 64
Mains over / under voltage (W / B)
Check the mains supply.
65
OpenTherm Plus communication error (W)
Sections 5.14 and 5.15.
66
Too many remote resets (L)
Power cycle the boiler.
70
Heat exchanger water flow fault, below minimum flow (B)
Check the pump and water flow.
Internal
94 – 99
Re-update request, programming mode, parameter mismatch / set, internal blocking / lockout
Contact your service provider.
Viessmann — Fault Finding
Codes from the Vitodens 050-W, 100-W and 200-W installation and service instructions (see the Manuals link on each series). Note the code before resetting. Follow safe isolation procedure before investigation. Reset only once the cause is cleared.
Vitodens 050-W / 100-W / 111-W — general
Reset
How to clear a lock-out
Press Reset on the display after noting the code. During commissioning an air-lock in the gas line can cause a fault: wait about 5 seconds, then press Reset. After code 416 is cleared, switch the boiler off and on again.
Vitodens 050-W / 100-W / 111-W — sensors
7 / 8
Cylinder temperature sensor lead break / short circuit (no DHW heating)
Check the sensor and its wiring at the cylinder sensor terminal.
13 / 14
Outside temperature sensor lead break / short circuit
Controls as if 0 °C outside. Check the sensor and wiring.
49 / 50
Flue gas temperature sensor lead break / short circuit
Check the sensor and wiring, then reset. Burner is in a fault state.
57 / 58
Room temperature sensor lead break / short circuit
Runs without room influence. Check the remote control setting and wiring.
182 / 183
DHW outlet sensor short circuit / lead break
No DHW heating. Check plug X7, cores 3 and 4, and the sensor.
184 / 185
Flow sensor / high limit short circuit / lead break
Check the sensor, lead and plug, then reset.
393 / 394
Second flue gas temperature sensor short circuit / lead break
Check the sensor and leads; replace the sensor if needed.
416
Flue gas temperature sensor positioned incorrectly
Fit the sensor correctly, then switch the boiler off and on again (mains reset).
Vitodens 050-W / 100-W / 111-W — water side and safety
59
Undervoltage on the supply
Burner locked and pump off. Check the mains voltage.
62 / 63
High limit safety cut-out / flue gas temperature limiter responded
Check the fill level, expansion vessel, flow rate and the 3-way valve. Reset once the flue has cooled.
345 / 373
Temperature limiter responded / heat transfer too low
Ensure adequate heat transfer: check the pump, 3-way valve, flow sensor and venting. 345 restarts after cooling.
74 / 87
System pressure too low / too high
Top up and vent the system, check the pressure sensor and the expansion vessel.
75
No flow rate
Open the valves, top up the system, check the flow sensor and pump.
89
Internal circulation pump blocked
Check the pump and replace if blocked.
766 / 767
Flue gas temperature too high
Clean the heat cell and service the boiler.
176 / 540
Condensate backup in the heat cell
Check the condensate system, drain and trap. Replace insulation blocks, electrodes and gauze if wet. Detach the fan unit first.
Vitodens 050-W / 100-W / 111-W — ignition, flame and gas
64 / 65
Flame lost during operation (burner restarts) / no or weak flame signal at start
Check the gas supply, flue gas recirculation, ionisation electrode and cable.
67 / 69
Ionisation current out of range (start / operation)
Check the gas supply, solenoid valve inlet strainer, and the gap between the electrode and burner gauze.
68
Flame signal present at burner start
Close the gas valve, disconnect the electrode lead, then reset.
71 / 371
Fan speed too low
Check the fan, its cables and power supply, and for blockage. Reset.
346 / 372 / 374 – 377 / 464 / 468
Ionisation calibration errors
Check the gas pressure and strainer, ionisation electrode and cable, flue system and flue gas recirculation, and condensate backup. For 377 also check the gas type setting. Detach the fan unit before removing the burner.
347 / 463
Flue gas recirculation / contaminated combustion air
Check and clean the flue system for back pressure or blockage.
348 / 354
Gas modulation valve fault / tolerance out of range
Check the multiple-connection setting. Replace the gas fan unit if it repeats.
349
Air mass flow not detected
Check the ventilation air supply and the burner gauze.
352
CO limit exceeded
Check the whole flue gas path for leaks and blockage.
353 / 357 / 467
Insufficient gas supply
Check the static and flow pressure, gas line and strainer.
359
No ignition spark
Check the electrode insulation, 230 V at the ignition module and the cables.
361 / 379
Flame signal absent or weak
Check the ionisation electrode and cable; look for contamination.
369 / 380 / 381 / 378
Flame lost after ignition or in operation
Check the gas supply, flue and flue gas recirculation, electrode and gauze clearance and contamination.
370
Gas or modulation valve does not close
Reset. If it repeats, replace the fan unit.
383 / 384
Possible gas line contamination
Check the gas line and supply pressure; replace the gas fan unit if needed.
364 / 365 / 366 / 367 / 70 / 77 / 161 / 163 / 355 / 385 – 410 / 417 / 418
HBMU (burner control) internal or earth faults
Reset first. For 385, 387 and 399 – 405 check the ionisation electrode and cable for an earth fault. Replace the HBMU if the fault persists.
382
Fault counter limit exceeded
Reset and review the fault history.
449 – 456 / 474 / 527 / 528
Program run monitoring / wrong HBMU parameter set
Reset. If it repeats, replace the HBMU or flash the correct parameter set.
457
Fan sluggish or blocked
Check the fan and replace it if heavily contaminated or noisy.
461 / 462 / 684
Flue gas damper / external gas safety valve / back draught safety device
Check the device and its connection.
Vitodens 050-W / 100-W / 111-W — communication and controls
78 / 103
Heat management unit and programming unit link disrupted
Check the cables and plugs.
95 / 738
OpenTherm remote control not connected / not configured
Check the connection, or set C.7 to 14 in the commissioning assistant.
104
External fault input active
Check the external appliance.
142 / 160
CAN bus communication fault
Check the fan unit and CAN plugs.
299 / 425
Date and time incorrect / time sync failed
Set the time and date.
471
System pressure sensor unavailable
Check the sensor, lead and plug, and the 5 V supply.
574 – 579
Room temperature sensor faults (heating circuits 1 and 2)
Check the external or remote control sensor and its setting.
979
Both plug 96 and OpenTherm are calling for heat
Use only one input.
980 / 981
DHW water flow below minimum
Check the cylinder flow and return are open, the DHW setting and the pump. A mains reset ends the pause time.
982
Heating circuit 1 pump running dry
Check the expansion vessel and circulation pump.
Vitodens 200-W (B2KB / B2HB) — sensors
10 / 18 / 19
Outside temperature sensor short circuit / lead break / wireless link interrupted
Controls as if 0 °C outside.
20 / 28
Flow temperature sensor (low loss header) short circuit / lead break
Regulates without it. Check the sensor and wiring.
30 / 38
Boiler water sensor short circuit / lead break
Burner blocked. Check the sensor and wiring.
50 / 58
Cylinder sensor short circuit / lead break
No DHW heating. Check the sensor and wiring.
51 / 59
DHW outlet sensor short circuit / lead break
No DHW heating. Check the sensor and wiring.
B0 / B8 / A3
Flue gas sensor short circuit / lead break / misplaced
Fit the sensor correctly and check its wiring.
Vitodens 200-W (B2KB / B2HB) — gas, ignition and flame
70 / 80 / 85
Gas pressure switch prevents start / insufficient gas supply / gas supply insufficient during calibration
Check the gas supply and gas train, and the supply pressure.
81
No ignition spark
Check the ignition module (230 V across X2.1 and X2.2) and the gas supply.
82 / EE
No flame signal / no flame at start
Check the ionisation electrode setting and purge the gas line.
83 / F3
Flame signal present at start
Check the gas valve and electrode.
E1 / E7 / E8 / EA / E9
Ionisation current too high / too low in calibration, out of range, implausible, repeated flame loss
Check the electrode, gas supply and flue.
EF / Fb
Flame lost during safety time / in operation
Check the gas supply, flue and flue gas recirculation.
84 / 95 / 96
CO limit exceeded / CO limiter tripped / CO limiter sensor fault
Check the flue gas path for leaks and blockage.
F8
Fuel or modulation valve will not close
Check the gas train.
F9 / FA / d3 / d4 / d5
Fan speed too low / fan not at idle / fan communication / no air flow / fan blocked
Check the fan, its cables, power supply and control.
FC / Fd
Gas train faulty or flue path blocked / burner control unit fault
Check the gas train, electrodes and EMC interference.
Vitodens 200-W (B2KB / B2HB) — safety, communication and modules
E3 / F1 / F2 / 74
Heat transfer too low / flue gas temperature limiter / temperature limiter responded
Ensure adequate heat transfer, then press Reset.
Eb
Shutdown during calibration
Check the gap between the ionisation electrode and burner gauze, the gas type setting and the flue system, then reset.
A9 / C5
Internal circulation pump blocked / variable speed pump communication error
Check the pump.
A7 / b1 / b5 / b7 / bF
Programming unit / internal / coding card / LON module faults
Check the connections; replace the faulty unit.
C1 – C4 / Cd / CF / E0 / d6 – d8
Extension modules and communication faults (EA1, AM1, OpenTherm, Vitocom, LON)
Check the module and its connection.
90 – 9F
Solar module / Vitosolic sensor and collector faults
Check the sensors, leads and the solar module.
E2 / E4 / E5 / EC / Ed / F0 / FE / FF
Calibration, 24 V supply, flame amplifier, parameter and internal control unit faults
Reset. Replace the control unit if it repeats. FE with B7 means the coding card is missing.
Ideal — Fault Finding
Common faults, codes and recommended actions for Ideal Logic, Logic+, Logic Max, Vogue and Independent ranges. Always confirm against the appliance's own fault code sticker or manual, and follow safe isolation procedure before investigation.
F1
Low system water pressure
Re-pressurise via filling loop to approx 1.0–1.5 bar cold; check for leaks and expansion vessel charge if pressure drops repeatedly.
F2 / L2
Flame loss / ignition lockout
Check gas supply and inlet pressure, ignition electrode condition/gap, and condensate trap/pipe for blockage or freezing before resetting.
F3
Fan fault
Check fan wiring/connector, PCB fan output, and flue/terminal for restriction; replace fan if faulty.
F4 / L4
Flow thermistor fault
Check flow NTC sensor resistance against manufacturer chart and wiring continuity; replace if out of range.
F5
Return thermistor fault
Check return NTC sensor resistance and connector; replace if faulty.
F6
Outside sensor failure
Check outdoor sensor wiring and connections (weather compensation models); replace sensor if open/short circuit.
F7
Low mains voltage
Check incoming electrical supply voltage and wiring connections; investigate building supply if voltage is genuinely low.
F9 / L9
Unconfigured or faulty printed circuit board (PCB)
Check PCB configuration/DIP switches per model; reconfigure or replace PCB if fault persists.
L1
Flow temperature overheat lockout / no water flow detected
Check pump operation, system flow, airlocks and open radiator valves; verify flow sensor before resetting.
L3
No flow thermistor fault / loss of water flow
Check pump, system flow rate and blockages; check flow thermistor wiring and resistance.
L5 / LC
Boiler has reset too many times in a short period (repeated lockout cycling)
Not a fault in itself — check fault history/log to find the underlying repeating fault (commonly F1 or L2) and address the root cause.
L6
False flame detection / flame signal fault
Check flame electrode condition, earthing/polarity, and PCB flame detection circuit.
C0
Central heating demand / signal issue
Check room thermostat/programmer wiring, settings and demand signal to the boiler.
C2
Boiler chip card (BCC) fault
Check the boiler chip card is correctly fitted and configured; replace if faulty (System/Regular models).
Status 0
Boiler idle / no current demand — not a fault
Normal standby display; if it persists with no heating/hot water response, check thermostat/programmer demand and wiring.
HVAC Mate
Air Conditioning
HVAC Mate
Fault Finding
Panasonic — Fault Finding
Common faults, codes and recommended actions for Panasonic air conditioning and air source heat pump units. Codes vary between domestic split, VRF and Aquarea ranges — confirm against the indoor unit display or manual before acting.
H07
Indoor/outdoor unit not communicating correctly
Check inter-unit wiring, connections and unit addressing/pairing.
H12
Indoor/outdoor capacity mismatch
Confirm the correct outdoor unit is paired with the indoor unit(s); check DIP switch/model settings.
H14 / H23
Indoor temperature or pipe sensor fault
Check sensor resistance and connector; replace sensor if reading is open/short circuit.
H97
Outdoor fan motor fault/lock
Check fan motor wiring, obstruction, and bearing; test motor resistance.
F16
Compressor overcurrent
Check refrigerant charge, compressor winding resistance, and supply voltage.
E9
Expansion valve (drive motor) fault
Check valve coil connection and drive signal from the PCB; replace if faulty.
Low output/no heating (Aquarea)
Low refrigerant charge or restricted flow
Check for leaks, refrigerant subcooling/superheat, and water/air flow through the system.
Grant — Fault Finding
Common faults, categories and recommended actions for Grant air source heat pumps (e.g. Aerona3). Exact fault codes and numbering vary by model and firmware — always check the controller display and installation manual.
High pressure fault
System pressure switch tripped
Check for restricted water/air flow, blocked filters, and closed valves; check pressure switch wiring.
Low pressure fault
Refrigerant low pressure switch tripped
Check for refrigerant leaks, and outdoor coil for ice/blockage/airflow restriction.
Communication fault
Loss of comms between outdoor unit and controller
Check the control cable/bus wiring and connections between outdoor unit and indoor controller.
Compressor overcurrent/overload
Compressor drawing excess current or overheating
Check supply voltage, compressor winding resistance, and refrigerant charge.
Defrost fault
Outdoor coil not defrosting correctly, icing up
Check defrost sensor, reversing valve operation, and outdoor fan for obstruction.
Flow/temperature sensor fault
Water flow or temperature sensor reading out of range
Check sensor wiring and resistance against manufacturer chart; bleed air from the system.
Low system flow
Insufficient water flow through heat pump
Check pump operation, strainer/filter for debris, and system balancing valves.
Vaillant — Fault Finding (Air Source)
Common faults, categories and recommended actions for Vaillant air source heat pumps (e.g. aroTHERM). These units use a different fault numbering system to Vaillant gas boilers — always confirm the exact code against the unit's own display and manual.
Low system pressure
Heating circuit water pressure too low
Re-pressurise via filling loop; check for leaks and expansion vessel charge.
Refrigerant pressure fault
High or low refrigerant pressure switch tripped
Check outdoor unit airflow, coil condition/icing, and check for refrigerant leaks.
Sensor fault (flow/return/outdoor)
Temperature sensor reading out of range or open circuit
Check sensor resistance and wiring; replace sensor if faulty.
Communication fault
Loss of comms between outdoor unit and indoor controller
Check eBUS/control wiring and connections between indoor and outdoor units.
Compressor fault
Compressor fails to start or trips on overload
Check supply voltage, compressor windings, and refrigerant charge/pressures.
Defrost fault
Outdoor unit icing up, defrost cycle not completing
Check defrost sensor and reversing valve; check outdoor fan and coil for obstruction.
Flow fault
Insufficient water flow through the heat pump
Check circulation pump, system filter, and bleed air from the circuit.
Mitsubishi — Fault Finding
Common faults, codes and recommended actions for Mitsubishi Electric air conditioning and Ecodan air source heat pump units. Codes are broadly consistent across the range but confirm against the unit's remote controller/display.
P1
Suction/intake air thermistor fault
Check thermistor resistance and connector; replace if open/short circuit.
P4
Drain sensor fault
Check drain sensor wiring and condition; clean or replace as needed.
P5
Drain pump fault / float switch tripped
Check drain pump operation and pipework for blockage; clean float switch.
P6
Freeze/overheat protection activated
Check refrigerant charge, filter cleanliness, and airflow across coil.
U2
Power supply voltage abnormality
Check incoming supply voltage and wiring connections at the outdoor unit.
E6 / E7
Indoor/outdoor communication fault
Check inter-unit control wiring and connectors; check unit addressing on multi-systems.
E9 (Ecodan)
Outdoor unit general fault
Check outdoor unit PCB fault log, compressor, and refrigerant pressures.
Daikin — Fault Finding
Common faults, codes and recommended actions for Daikin air conditioning and air source heat pump (Altherma) units. Confirm the exact code against the unit's remote controller/display, as numbering can differ by range.
A1
Indoor unit PCB fault
Check indoor PCB connections; replace PCB if fault persists after reset.
A6
Indoor fan motor fault
Check fan motor wiring and for obstruction; test motor resistance.
E1 / E3
Outdoor PCB fault / high pressure fault
Check outdoor PCB, high pressure switch, and airflow/blockage at outdoor coil.
E4
Low pressure fault
Check for refrigerant leaks and restricted flow; check low pressure switch.
E7
Outdoor fan motor fault
Check fan motor wiring, obstruction, and bearing condition.
F3
Discharge pipe temperature too high
Check refrigerant charge, airflow, and expansion valve operation.
U4 / U2
Communication fault / power supply fault
Check inter-unit wiring and incoming power supply; check unit addressing on multi-systems.
HVAC Mate
Commercial Boilers
HVAC Mate
Commercial
Plantroom Ventilation
Estimates permanent free area ventilation for a plantroom based on total net heat input and flue type, following commonly used commercial gas industry allowances (BS 6644 / IGEM guidance). Open-flued: 5.5 cm²/kW low level + 2.75 cm²/kW high level (combustion + cooling air), direct to outside air. Room sealed: a smaller cooling-only allowance, commonly around 2 cm²/kW at a single high-level opening. Always confirm against the specific appliance manufacturer's instructions and the current edition of the standard, as requirements vary by appliance type, plantroom air change rate, size and location.
Open-flued appliances need ventilation for both combustion air and cooling, using the full low/high level allowance below.
Enter a heat input greater than 0.
Where not all appliances in the plantroom can fire at the same time, ventilation can be based on the maximum probable simultaneous load rather than the full connected total. Only apply a reduced factor where this is confirmed by the system design/controls — if in doubt, use 100%.
Effective Heat Input Used for Calculation
0 kW
Low Level Free Area (air inlet)
0 cm²
High Level Free Area (air outlet)
0 cm²
1. Volume & Purge
Used for both the purge volume and the correct IGEM/UP/1B Ed. 4 tightness table (NG, LPG and LPG/Air each have different permissible drops).

Add Pipework Sections
Enter a length greater than 0.
Pipework + Meter Volume
0.0000 m³
+ Fittings Allowance (IVf, 10% of pipework)
0.0000 m³
Total Installation Volume (IV)
0.0000 m³
IGEM/UP/1B Ed. 4 Tightness Allowance
-
5. Purging
No pipework entered yet -- purging is based on the Installation Volume, so enter your meter and pipe runs there first.
Installation Volume (from the previous screen)
0.0000 m³
Fittings on Site
IGEM/UP/1B Ed. 4 accounts for fittings as a flat 10% of pipework volume, already included above. This list is for your own on-site record -- it doesn't change the calculated figures.
Required Purge Volume (PV = 1.5 × IV)
0.0000 m³
2. Tightness Testing
Existing (appliances connected)
New Installation
A new installation must show no pressure drop at all. The IV-based allowance below only applies to an existing installation with appliances connected.
Permissible Pressure Drop (IGEM/UP/1B Ed. 4)
-
0.0s
IGEM/UP/1B Ed. 4 standard duration: allow 1 minute for the pressure to stabilise, then time the test for exactly 2 minutes.
Start the timer the moment you record the start pressure, stop it the moment you record the end pressure.
Pressure Drop / Status
0.0 mbar
Test Duration
0.0s
3. Gas Flow Rate
Imperial
Metric
0.0s
Start the timer at the beginning of a dial revolution, and stop it the instant the dial completes exactly one revolution.
Time it with the stopwatch above before calculating.
If your meter shows the live flow rate, enter it here with the appliance running and tap Calculate. This is converted straight to kW — no readings or timer needed. Leave blank to use the two-reading method below instead.
Enter a flow rate greater than 0.
— OR —
Metric meters show a digital cumulative reading rather than a dial to time — take two readings a short time apart instead.
Just type the digits as shown on the meter, no decimal point needed -- the last 3 digits are treated as litres (e.g. 1234150 means 1234.150 m³).
End reading must be greater than the start reading.
Use the CV shown on the gas supplier's certificate or meter data — this defaults to a typical UK natural gas value, but always confirm against the actual site figure.
This result looks unusually high for a domestic appliance -- double check your meter readings include the decimal point in the right place (e.g. 01234.150, not just 150).
Heat Input Output
0.00 kW (GROSS)
0.00 kW (NET)
Net Reading (Volume Used)
0.000 m³
Volumetric Rate
0.00 ft³/hr
4. Heating Heat Loss
All dimensions must be greater than 0.
Required Radiator / Boiler Output
0.00 kW
Heat Output in BTU/hr
0 BTU/hr
Detailed Heat Loss Calculator
Room-by-room fabric & ventilation heat loss (simplified BS EN 12831 method). External design temp fixed at -2°C. For guidance only — confirm against full survey for accurate radiator/boiler sizing.
All dimensions must be greater than 0.
Required Radiator / Boiler Output
0.00 kW
Heat Output in BTU/hr
0 BTU/hr
Property Rooms
Property Total Heat Loss (0 rooms)
0.00 kW
Total BTU/hr
0 BTU/hr
6. AC Cooling Load
All dimensions must be greater than 0.
Required Cooling Capacity
0.00 kW
Cooling Capacity in BTU/hr
0 BTU/hr
7. Refrigerants & PT Slider
ODP Rating
0.00
GWP Rating
675
Boiling Pt @ 0 barg
-51.7 °C
Safety Class
A2L
Pressure / Temperature Calculator
Gauge bar(g)
Absolute bar(a)
bar(g)
Gauge is what a manifold set reads on site. Absolute = gauge + 1.01325 bar (atmospheric).
Bubble Point (Liquid)
0.0 °C
Subcooling Baseline
Dew Point (Vapor)
0.0 °C
Superheat Baseline
Temperature Glide Info
Near-azeotropic: Negligible temp glide.
Values are interpolated from standard refrigerant P-T reference points. For safety-critical or legal work, cross-check against the manufacturer's current P-T card.
8. Site PDF Report
Saved Calculations Log
No calculations added yet. Run a calculation and tap 'Add to Report'.